Parameters

6.3.2 Motion Setting Parameter Details

6-18

Table 6.2 Motion Setting Parameter Details

No.

Name

Register

Number

Bit Name

Description

Default

1

RUN Mode
Settings
(RUNMOD)

OWC000

Set the RUN mode, such as Control Mode and Alarm Reset. The bit configuration is
shown below.

Bit

0

Speed Refer-
ence Output
Mode (NCON)

Used to set Speed Reference Output Mode.

0

1

Torque Refer-
ence Output
Mode (TCON)

Used to set Torque Reference Output Mode.

0

2

Position Control
Mode (PCON)

Used to set Position Control Mode.

1

3

Phase Control
Mode (PHCON)

Used to set Phase Control Mode

0

4

Zero Point
Return Mode
(ZRN)

Used to set Zero Point Return Mode.

0

5

Phase Control
Test Mode
(PHTEST)

Set whether the results of phase reference calcula-
tions and PI control calculations are valid or not in
Phase Control Mode.
0: Not valid
1: Valid
When Not Valid is selected, this parameter func-
tions much like the Speed Reference Output Mode
with the Filter Time Constant and Acceleration/
Deceleration Time Constant set to 0.

0

6

Alarm Clear
(ACR)

The following monitor parameters will be cleared
when this bit turns ON.

• IWC000 RUN Status: Error Counter Over (bit 0)

and Motion Setting Parameter Setting Error (bit
1)

• Alarms (ILC022)

0