C.1 motion fixed parameters – Yaskawa MP940 User Manual

Page 501

Advertising
background image

Motion Parameter Tables

C.1 Motion Fixed Parameters

C-2

C.1 Motion Fixed Parameters

Motion fixed parameters are set only once unless there is a configurational, specification, or
other machine-related change. They are set from the Fixed Parameter Setting Screen on the
CP-717.

Table C.1 Motion Fixed Parameters

No.

Name

Bit Name

(Setting Range)

Meaning

Remarks

1

Axis Selection
(USESEL)

0 or 1
(Default = 1)

0: Not used
1: Use

7

Rated Motor Speed
Setting (NR)

1 to 32000

1 = 1 r/min

Used in simulation mode

13

DI Latch Signal
Selection
(DIINTSEL)

0 or 1
(Default = 0)

0: DI input signal
1: C pulse input signal

14

Additional Function
Selections
(AFUNCSEL)

Bit 0 to 1: Not used.

-

-

Bit 2: LIMITSEL

Limit Switch Signal Selection

0: Use OBC001F.
1: Use the DI signal.

Bit 3 to 6: Not used.

-

-

Bit 7: MCMDSEL

Motion Command Code Selec-
tion

0: Not used.
1: Use.

Bit 8 to 11: Not used.

-

-

Bit 12 to 15:
EOV_MULTI

Deviation error detection coeffi-
cient

0 to 15

15

Not used.

-

-

-

16

Simulation Mode
Selection

0 to2
(Default = 0)

0: Normal operation mode

1: Simulation mode

17

Motion Controller
Function Selection
Flags
(SVFUNCSEL)

Bit 0 to 3: 0 to 7
CMD_UNIT

Reference Unit Selection

0: pulse
(Electronic gear dis-
abled)

1: mm

2: deg

3: inch

Bit 4: USE_GEAR

Electronic Gear Selection

0: Disabled
1: Enabled

Bit 5: PMOD_SEL

Axis Selection

0: Finite length axis
1: Infinite length axis

Bit 6: USE_BKRSH

Backlash Compensation Enabled
Selection

0: Disabled
1: Enabled

Bit 7: USE_SLIMP

Positive Software Limit Selection 0: Disabled

1: Enabled

Bit 8: USE_SLIMN

Negative Software Limit Selec-
tion

0: Disabled
1: Enabled

Bit 9: USE_OV

Override Selection

0: Disabled
1: Enabled

Bit 10: INV_DEC

Deceleration Limit Switch Inver-
sion Selection

0: Do not reverse.
1: Reverse.

Advertising