Yaskawa MP940 User Manual

Page 507

Advertising
background image

Motion Parameter Tables

C.2 Motion Setting Parameters

C-8

23

Phase Bias Setting
(PHBIAS)

OLC016

-2

31

to 2

31

-1

(Default = 0)

1 = 1pulse

25

Speed
Compensation
Setting (NCOM)

OWC018

-32768 to 32767
(Default = 0)

1 = 0.01% (100 = 1.00%)

26

Proportional Gain
Setting (Pv)

OWC019

0 to 32767
(Default = 300)

1 = 0.1/s (300 = 30.0)

27

Integral Time
Setting
(Ti)

OWC01A

0 to 32767
(Default = 300)

1 = 1ms (0 = No integration) (300 = 0.300s)

28

Torque Reference
Setting
(TREF)

OWC01B

-32768 to 32767
(Default = 0)

1 = 0.01% (10000 = 100.00%)

29

Speed Limit Setting
(NLIM)

OWC01C

-32768 to 32767
(Default = 15000)

1 = 0.01%
(15000 = 150.00%)

31

Pulse Bias Setting
(PULBIAS)

OLC01E

-2

31

to 2

31

-1

(Default = 0)

1 = 1 pulse

33

Motion Command
Code
(MCMDCODE)

OWC020

0 to 65535
(Default = 0)

0: NOP

NO command

1: POSING

Positioning

2: EX_POSING

External position

3: ZRET

Zero point return

4: INTERPOLATE

Interpolation

5: ENDOF_
INTERPOLATE

Interpolation end seg-
ment

6: LATCH

Interpolation with latch

7: FEED

Feed

8: STEP

Step

9: ZSET

Zero point setting

10 to 65535: Not used.

No.

Name

Register

No.

Bit Name

(Setting Range)

Meaning

Remarks

Advertising