User operation error status in ladder programs, User operation error status in ladder programs -11 – Yaskawa MP3200 Troubleshooting Manual User Manual

Page 137

Advertising
background image

7.5 System Register Configuration and Error Status

User Operation Error Status in Ladder Programs

7-11

T

roubleshooting System Errors

User Operation Error Status in Ladder Programs

The user operation error status shows operation errors in the ladder programs.

Broadly speaking, the user operation error status includes two main types of status.

Operation errors can be confirmed in system registers SW00080 to SW00089 (user operation error status)
and SW00110 to SW00189 (user operation error status details).

Drawing Type

Error Description Register Addresses

Contents

DWG.A

Error Count

SW00080

• Error Count

Gives the number of errors that have occurred.

• Error Code

Gives the details of the error.
0 hex: Operation error

User Operation Error Code -1: Operation

Errors (page 7-12)

x hex (x = 1, 2, 3): Index error

User Operation Error Code -2: Index Errors

(page 7-13)

Error Code

SW00081

DWG.I

Error Count

SW00082

Error Code

SW00083

DWG.H

Error Count

SW00084

Error Code

SW00085

Reserved for system.

SW00086 and

SW00087

DWG.L

Error Count

SW00088

Error Code

SW00089