background image

4.2 Troubleshooting Motion Errors

Checking Status and Alarms of a Reference-type SERVOPACK with MECHATROLINK-III Communications

4-22

Σ-7-series SERVOPACKs

Register
Address

Name

Code

Meaning

IW2D

SERVOPACK
Alarm Code

020

Parameter Checksum Error

021

Parameter Format Error

022

System Checksum Error

024

System Alarm

025

System Alarm

030

Main Circuit Detector Error

040

Parameter Setting Error

041

Encoder Output Pulse Setting Error

042

Parameter Combination Error

044

Semi-closed/Fully-closed Loop Control Parameter Setting Error

050

Combination Error

051

Unsupported Device Alarm

070

Detected Motor Type Change

080

Linear Encoder Scale Pitch Setting Error

0B0

Canceled Servo ON Command Alarm

100

Overcurrent Detected

300

Regeneration Error

320

Regeneration Overload

330

Main Circuit Power Supply Wiring Error

331

Power Monitor Input Signal Error

400

Overvoltage

410

Undervoltage

450

Main Circuit Capacitor Overvoltage

510

Overspeed

511

Overspeed of Encoder Output Pulse Rate

520

Vibration Alarm

521

Autotuning Alarm

550

Maximum Speed Setting Error

710

Maximum Momentary Overload

720

Maximum Continuous Overload

730, 731 Dynamic Brake Overload

740

Overload of Surge Current Limit Resistor

7A1

Internal Temperature Error 1 (Control Board Temperature Error)

7A2

Internal Temperature Error 2 (Power Board Temperature Error)

7A3

Internal Temperature Detector Error

7AB

Built-in Fan in SERVOPACK Stopped

810

Encoder Backup Alarm

820

Encoder Checksum Alarm

830

Encoder Battery Alarm

840

Encoder Data Alarm

850

Encoder Overspeed

860

Encoder Overheated

861

Overheat

890

Encoder Scale Error

891

Encoder Module Error

8A0

External Encoder Error