Dimensions and technical specifications, Chapter 3 installation and use manual, Airsystem e50 technical specifications – MCZ AirSystem 70 DX User Manual

Page 11: Flue pipe, Airsystem e60 technical specifications

Advertising
background image

Chapter 3

INSTALLATION AND USE MANUAL

page

11

Dimensions and technical specifications

Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited

3. DIMENSIONS AND TECHNICAL SPECIFICATIONS

Airsystem E50

Technical specifications

Fuel type

Wood - Logs

Hourly consumption

2.3 kg/h – 1.6 kg/h

Nominal thermal power

kW 8.2 Kcal 7052

Efficiency 75.2%
Heatable volume *

176/40 - 201/35 - 235/30

Minimum draught

12 Pa / 0.12 mbar

Smoke temperature

206 °C

Smoke outlet

Ø 18 cm

Fire box dimensions

Net weight

External combustion air outlet

cm² 150

CO emission in smoke (13 %O

2

) 0.23%

Massive smoke capacity

12.5 g/s

Flue pipe

Up to 5 m

20x30 cm Ø22

Between 5 and 7 m

20x20 cm Ø20

Over 7 m

18x18 cm Ø18

Note

665

640

327

345

510

2

0

-4

0

1

4

0

0

-1

4

2

0

3

4

5

-3

6

5

590

5

0

0

5

5

5

560

Ø180

2

6

0

Intermittent combustion unit
* Data may vary according to the fuel used


Airsystem E60

Technical specifications

Fuel type

Wood - Logs

Hourly consumption

3.1 kg/h – 2.2 kg/h

Nominal thermal power

kW 10 Kcal 8600

Efficiency 74.8%
Heatable volume *

215/40 - 246/35 - 287/30

Minimum draught

12 Pa / 0.12 mbar

Smoke temperature

300 °C

Smoke outlet

Ø 18 cm

Fire box dimensions

Net weight

External combustion air outlet

cm² 150

CO emission in smoke (13 %O

2

) 0.08%

Massive smoke capacity

12 g/s

Flue pipe

Up to 5 m

20x30 cm Ø22

Between 5 and 7 m

20x20 cm Ø20

Over 7 m

18x18 cm Ø18

Note

748

588

1

3

2

8

-1

3

4

8

2

0

-4

0

4

1

1

5

7

7

3

4

0

-3

6

0

576

4

9

1

2

6

2

515

Ø180

700

Intermittent combustion unit
* Data may vary according to the fuel used

Advertising