Turning on and off, Manual mode, Automatic mode – MCZ AirSystem 70 DX User Manual

Page 26

Advertising
background image

Chapter 4

INSTALLATION AND USE MANUAL

page

26

Installation and assembly

Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited

• Change operating mode from manual to automatic and vice

versa (red key)

• Variation of the 4 speeds of the fan (yellow keys)

4.10.2.

Turning on and off

TURNING ON: Press and hold the blue ON/OFF button of the radio

remote control to turn the fan on at the first speed

in MANUAL mode. The control unit emits a short

beep that identifies 1

st

speed in manual mode.

TURNING OFF: Press and hold the blue ON/OFF button of the radio

remote control to place the device in STAND-BY

mode, which is signalled by a very long beep, and

shut down the fan.

4.10.3.

Manual mode

By default, when turned on using the ON/OFF button, or simply by

clicking the red MAN/AUT button, the system goes into MANUAL mode.

This mode can be recognized by the fact that all of the sound

signals emitted by the control unit in this status are short

beeps and the fan is always on regardless of the temperature.
The yellow + and - buttons are used to increase/decrease the speed of

the fan from 1

st

to 4

th

and vice versa. The control unit responds with a

number of short beeps that corresponds to the selected speed:

1

st

speed

= 1 short BEEP

2

nd

speed

= 2 short BEEPS

3

rd

speed

= 3 short BEEPS

4

th

speed

= 4 short BEEPS

Regardless of whether the fireplace stove is on or not, the fan comes

on, emitting air at the set speed.

4.10.4.

Automatic mode

Once ventilation is turned on in manual mode, by pressing the red

MAN/AUT of the radio remote control, the device goes to AUTOMATIC

mode. The mode can be recognized by the fact that all the sound

signals emitted by the control unit in this status are long

beeps.
The yellow + and - buttons are used to increase/decrease the speed of

the fan from 1

st

to 4

th

and vice versa. The control unit responds with a

number of short beeps that corresponds to the selected speed:

1

st

speed

= 1 long BEEP

2

nd

speed

= 2 long BEEPS

3

rd

speed

= 3 long BEEPS

4

th

speed

= 4 long BEEPS

Ventilation is turned on and off exclusively by the temperature of the

thermostatic probe.

AUTOMATIC START BY MEANS OF THE PROBE:
If the temperature detected by the probe is greater than 45°C, the fan

comes on at the set speed (1

st

speed) and an internal timer is activated