Electric fan, Control unit fc 715, Radio remote control – MCZ AirSystem 70 DX User Manual

Page 37: Probe, Wiring

Advertising
background image

Chapter 6

INSTALLATION AND USE MANUAL

page

37

Maintenance and cleaning

Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited

6.1.5.1.

Electric fan

Periodically, and at least at the end of each winter, it is advisable to

clean the fan blades, which may have suctioned up dust or other small

foreign bodies due to the static pressure exercised by the fan along the

air ducts.
Clean the fan blades only with compressed air or with a vacuum

cleaner. Take care not to damage the rotor or the fan blades.

Do not use any sort of rigid device which might bend

the blades. When rotating, bent blades will produce

more noise than normal due to off-axis rotation of

the fan.

6.1.5.2.

Control unit FC 715

Does not require any special maintenance if located as instructed in

chapter 4.9.3. From time to time, you may want to check the condition

of the fuse near the plug that provides power to the control unit.

6.1.5.3.

Radio remote control

On a yearly basis, it is advisable to replace the batteries of the radio

remote control to ensure efficient transmission of the data to the

control unit.
Check that the red light in the upper left-hand corner of the radio

remote control comes on when buttons are pressed.
If for any reason (electromagnetic fields, voltage surges, etc.) the

remote control stops transmitting data, to change the frequency, re-

calibrate the frequency using the procedure in

chapter 4.10.4 or

4.11.6, without necessarily moving the small switches located in the

battery compartment.

6.1.5.4.

Probe

The probe does not require any maintenance. Just make sure that

ashes or dirt do not build up around it. Ashes or dirt may act as

insulation and invalidate the activation times of the device.

6.1.5.5.

Wiring

Make sure the wiring is in good condition and that it is not near the hot

body of the fireplace stove. Heat may damage it.

6.2. CLEANING TO BE DEALT WITH BY SPECIALIZED

TECHNICIAN

6.2.1. Cleaning flue pipe

Mechanical cleaning of the flue pipe is recommended at least once a

year. Excessive deposits of unburnt solid material can cause problems

with the evacuation of smoke, and gives rise to a risk of chimney fires.

ON