Chapter 5

INSTALLATION AND USE MANUAL

page

30

Operation

Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited

5. OPERATION

5.1. PRE-LIGHTING WARNINGS

Do not touch the fireplace stove when it is lit for the first

time. During this phase, the paint finishes drying and

hardens. If you touch the paint, you may expose the steel

surface.
It is good practice to provide plenty of ventilation in the

room during the initial lighting, as the stove will give off a

small amount of smoke and smell of paint.
If necessary, touch up the paint with the aerosol spray in

the original colour (see “Fireplace stove accessories and

inserts")

Do not stay near the fireplace stove, and as previously mentioned,

ventilate the room. The smoke and the smell of paint will vanish after

about one hour of operation. There are no health risks involved.
The fireplace stove will be subject to expansion and contraction during

the stages of lighting and cooling down, and may therefore make slight

creaking noises.
This phenomenon is absolutely normal, the structure being made of

sheet steel, and must not be considered a fault.

It is very important not to bring the stove up to full

heat immediately. Bring it up to temperature

gradually.
This avoids damages to welds and the steel

structure.

Do not demand full heating
performance straight away!

5.2. OPERATING TEST

ATTENTION!!

BEFORE PROCEEDING IN ANY WAY WITH THE

INSTALLATION OF THE CLADDING, CARRY OUT A

GENERAL TEST OF THE FIREPLACE STOVE AS

FOLLOWS:

Raise and lower the fire door 7-8 times to ensure

fluid sliding and that the counterweights do not

produce noise when they come into contact with

the structure (if this anomaly occurs, review chapter

4.6)

Check that all of the wiring and the control unit

(if the kit VF is installed) are always placed at a

distance from the hot body of the fireplace stove.

Test the ventilation kit at all speeds and in all

modes (if kit VF is installed)

Light the fire at low power to ensure the smoke

connections do not leak smoke or soot. Before

lighting, however, read Chapter 5.