Chapter 5

INSTALLATION AND USE MANUAL

page

33

Operation

Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited

5.5. LOADING THE FUEL

For normal fuel loading, lift the handle as shown in

figure 27. To close the door, do the opposite.
During use, the metallic structure, the handle and the glass

become very hot. Use the thermal glove provided when

handling these parts.
During normal use, always keep the fire door completely down

and closed. Intermediate positions cause abnormal combustion (forge

effect), rapid wood consumption, and may cause smoke to leak out due

to the high temperature of the fire box.
Open the door only to add fuel, and only for brief periods of

time.
The fireplace stove works best and provides the greatest yield when the

door is closed, because the hermetic combustion chamber and the

calibrated inlet of oxygen allow increased performance.

5.6. CONTROL OF COMBUSTION

PRIMARY AIR
The fireplace stove is equipped with primary air emission from the front

part which ensures combustion and helps keep the glass clean. Moving

the lever to the right provides the full aperture, and more rapid

combustion, while moving it to the left closes the opening, with slower

burning.
SECONDARY AIR
Adjustment is performed using the same lever as for the primary air.

Secondary air comes out in proportion to the primary air. This balance

is pre-calculated; the user cannot change it, as this may cause incorrect

adjustment. This will prevent excessive combustion.

The use of damp or treated wood emits a higher quantity of

smoke than normal that can dirty glass faster. Also the low

performance of the flue pipe can jeopardise glass cleanliness

since smoke remains in the combustion chamber longer than

normal.

5.6.1. Removal of upper deflectors to improve

release of smoke

If your flue pipe is not in the best condition and when you check

combustion you notice that:

• The smoke remains in the smoke mouth for too long
• The flame is very red and feeble
• The glass gets dirty very quickly
• The internal refractory material in Alutec® is very dirty

it probably indicates poor performance of the flue pipe.

Therefore it is necessary to facilitate evacuation of smoke.
To resolve this issue, the MCZ Airsystem line lets you easily modify the

upper deflector assembly, which normally deals with carrying the

smoke into the flue pipe.

MIN

MA

X

Figure 28 – Adjustment of primary/secondary air.

Figure 27 – Opening/closing the fire door