4.7. EXTERNAL AND INTERNAL AIR INTAKE

4.7.1. Fireplace stove with natural ventilation

If the fireplace stove is installed with natural ventilation, i.e. with no

electric fan, make an external combustion air intake of 300 cm² net

behind the unit so that fresh air always flows beneath the fireplace

stove.

(figure 7)

You must comply with this instruction fully, because otherwise a lack of

oxygen may compromise combustion and calorific energy of the

product.

4.7.2. Fireplace stove with forced ventilation

4.7.2.1.

Ducts for kit VF 480-620 m

3

/h

If the fireplace stove is installed with forced ventilation, i.e. using a fan

of 480 or 620 m

3

/h, place air intakes and ducts as follows:

for proper air circulation in the room, it is advisable to connect one

of the two ducts to the exterior of the home, creating an air intake

of 150 cm², in order to draw in clean, fresh air; place the other in

the room where the fireplace stove is installed (also of 150 cm²).
This mode allows a proper mix of the air in the room of installation

and better cooling of the structure of the fireplace stove.

(Figure 8)

If you cannot make this kind of connection, you will still need to

connect both ducts, whether they are both directed to the exterior or

the interior. Depending on the selection, you will have operating

temperatures that are slightly above or below average but which do not

compromise proper operation of the product.

ALWAYS CONNECT THE TWO DUCTS AND RUN THEM

OUTSIDE THE CLADDING OF THE FIREPLACE STOVE.
IF THIS DIRECTIVE IS NOT OBSERVED, THE FAN,

HAVING GREATER STATIC PRESSURE, MAY ALSO

INTAKE AIR INTENDED FOR THE FRONT GRILLE OF

THE FIREPLACE STOVE AND REQUIRED FOR

COMBUSTION

4.7.2.2.

Ducts for kit VF 180 m

3

/h (Airsystem B70)

Differently from the kit VF 480-620 m

3

/h, the kit VF 180 m

3

/h does not

require ducts, since the lower power of the fans and their position

with respect to the fireplace stove allow proper operation of the system

provided a considerable quantity of air is provided under the unit.
Considering that this type of fireplace is normally set in an internal wall

of the home and it is almost never possible to provide ducts to the

outside of the home as with the previously described model, the

ventilation air must all be drawn from the room of installation, using the

air intakes on each side of the cladding
It is necessary to provide two air intakes with a net minimum section

of 150 cm

2

on both sides of the cladding that allow a continuous

exchange of oxygen under the fireplace stove

(figure 9).

Figure 7 – Intake for external combustion air

and for natural ventilation

Figure 8 – Air intakes for ducts of fan and

combustion air intake.

Air intake of 300 cm

2

for

combustion air and natural
convection

Internal and external air
intakes of 150 cm

2

for forced

ventilation air.

Combustion air intake of
150 cm

2