SLIM-BASIC COMFORT AIR KIT

Chapter 3

USE AND MAINTENANCE MANUAL

page

11

Basic comfort air kit

Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited

 prepare a plasterboard shape measuring 220mmx191mm in

order to create a cover for the kit flap. This way, once the wall

has been plastered and painted, the fan kit will be concealed

from view. Secure the plasterboard cover to the flap using

silicone.






















We recommend you:

Construct ducting no more than 8 m in length.

 ensure there is suitable insulation for the ducting so that the heat

energy generated is not lost heating the masonry alone.

In closed fireplaces with several air inlets, duct the front

air outlets (A) where more heat builds up than at the rear

outlets (P).







P

A

SILICONE

PLASTERBOARD
COVER
TO FIT ONTO
THE FAN KIT
FLAP