SLIM-BASIC COMFORT AIR KIT

Chapter 3

USE AND MAINTENANCE MANUAL

page

14

Basic comfort air kit

Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited

2.2.2. Replacing the fan

CAUTION!
CUT OFF THE 230 V SUPPLY BY DISCONNECTING THE

CONTROL UNIT FROM THE MAINS.

 Lift the flap

 If the control unit is seated in the fan kit, remove the fixing

screws and disconnect the various electrical connections.

 Loosen the 4 screws “P” (two to the left and two to the right)

and remove the panel to gain access to the fan

 Remove the rubber sleeve “Q”

 Remove the screw “R” at the front and the screw at the rear

“S” opposite the fixing bracket

 Remove the fan connection faston connector

 now the fan can be removed and replaced

CAUTION!
MAKE SURE YOU SECURE ALL WIRES WHEN YOU

DISCONNECT THEM.
YOU WILL BE UNABLE TO RETRIEVE THEM IF THEY

FALL INTO THE CLADDING.

Important!
All electrical connections must be made by qualified

staff in accordance with the applicable Laws in force in

all countries, using suitable equipment and according

to the diagram provided in this manual. All operations

must be performed with the 230V 50 Hz mains power

supply cable disconnected.
Mcz will not be held liable for personal or property

damage due to incorrect connections or improper

device use.

P

Q

R

S