SLIM-BASIC COMFORT AIR KIT

Chapter 3

USE AND MAINTENANCE MANUAL

page

19

Basic comfort air kit

Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited

GHOST lamp insertion

As mentioned in paragraph 2.2.3, for this type of hot air outlet, only ducting to the left or right is possible. The

glass insertion mechanism is the same as for the Flip and Float lamps.
The actuator with the extension - used to open the lamp glass - is fitted onto the hot air outlet support for the

Ghost lamp. The actuator must always be seated at the top, so if the support is turned, the actuator and

the extension need to be moved to the top hole.
Consequently, for this type of hot air outlet, you need to envisage the electrical connection for the actuator as

well, according to the wiring diagram shown above.
In the GHOST hot air outlet, only a single lamp holder with a lamp can be installed at the bottom, where the

lamp glass lifts up.















IMPORTANT!
The cable to connect the lamp/fan is made of silicone

to withstand high temperatures. If the cable is

extended (to more than 2.5 m) and in any case always

make sure the cable does not touch hot parts of the

unit, or air connection pipes inside the cladding or

structure.

ACTUATOR

W/EXTENSION

LAMP HOLDER+LAMP – TO

BE FITTED AT THE

BOTTOM

GHOST