Basic comfort air kit

Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited

2.4. REMOTE CONTROL

2.4.1.

Light operation (keys 1-3)

Turn the lights on by holding down key “1” on the remote control;

prolonged pressure increases the intensity of brightness, while pressing

key “3” decreases brightness until the lights go out completely.

The lesser the brightness the lower the electricity consumption.

2.4.2.

Fan operation (keys 2-4)

Turn the fans on by holding down key “2” on the remote control;

prolonged pressure increases the speed, shown by the number of LEDs

illuminated on the board. There are 4 different speeds, corresponding

to 4 different air flows.

Press key “4” to decrease the speed until the fans are turned off

completely.

If the temperature sensor (optional) is not connected to the control

unit, the operation of the fans is independent from the temperature of

the air in the closed fireplace.

2.5. KIT OPERATING MODES

2.5.1.

Manual operation

With the temperature sensor not connected, the fans are operated

directly from the remote control.

2.5.2.

Automatic operation with temperature

sensor

 When the temperature sensor is connected, press ON/OFF key

(2) and, if the closed fireplace is still cold, the 4 LEDs start to

flash. The fan starts to rotate at low speed to encourage the

flow of air towards the sensor;

 With the closed fireplace warm, when 50°C are reached (the

LEDs stay on), the motor is operated at the value requested by

the customer; to avoid any inadvertent ON/OFF operations, the

reading of the sensor is inhibited during the first 5 minutes of

operation

 Shut-down: below 42°C (from 41° to 39.5°C), the motor is

operated at minimum speed again and the LEDs begin to flash

again. This makes it possible to make the most of all the

residual heat from the closed fireplace, as well as immediate

restarting when the flame is revived

 Below 39.5°C, the motor and control unit are turned off; the

control unit will have to be turned back on for restarting.