Theoretical notions for installation

Technical service – MCZ GROUP S.p.A. all rights reserved - Reproduction prohibited

must be suitably sized to accommodate the draught/smoke

disposal requirements necessary for the correct functioning of

the product (EN13384-1).

It must preferably have a circular interior section.

If pre-existing and previously used, it must be cleaned.

The flue pipe is of primary importance for the correct

functioning and safety of your fireplace stove.

2.5.1. Examples of flue pipes














Square or rectangular section flue pipes must have rounded internal

corners with radius not less than 20mm. For the rectangular section,

the ratio between internal dimensions must be ≤1.5.
The sections/lengths of the flue pipe shown in the technical data table

are guidelines for correct installation. Any alternative configurations

must be suitably sized in accordance with EN13384-1.
The smoke duct should be equipped with a solid material collection

chamber at the mouth of the smoke duct to be easily opened with an

airtight door.

IMPORTANT !

In the event of doubt on your chimney flue

operations or that its dimensions are different from

those recommended, we highly suggest an

authorised MCZ technician inspect and measure

chimney flue performance (micro-gauge

measurements)
MCZ s.p.a. shall not be held liable for poor operation

of the fireplace stove that is due to a flue pipe of

improper size or installation that does not comply

with provided requirements.

Stainless steel 316 flue

pipe with dual chamber

insulated with ceramic wool

or equivalent resistant to

400°C.
EXCELLENT

Flue pipe in refractory brick

with insulated double wall and

external coat of cement mix

lightened with honeycomb

material such as clay.
GOOD

Traditional square section

clay flue pipe with insulating

hollow inserts.
GOOD

Avoid flue pipes with internal

rectangular sections whose

larger side is double the smaller

such as 20x40 or 15x30.
AVERAGE