4.10. UNIT CLADDING

Only after finishing all the installation operations of

the fireplace stove, connecting the smoke duct,

electric and hydraulic connections and carrying out

the first lighting, is it possible to begin the cladding

of the unit

4.10.1. INSULATION OF FIREPLACE STOVE

The fireplace stove must also always be separated from nearby

walls and ceilings.
If necessary, use insulating materials to insulate the walls that are in

contact with the unit if they may be damaged or catch fire (walls made

of wood, plasterboard, etc.).

4.10.2. INSULATING A WOODEN BEAM

The wood beam must be protected with adequate insulation from

heated parts to prevent the risk of fire or damage of the cladding.

4.10.3. Decorative hood

Before building the decorative hood we strongly recommend a

general test of the fireplace stove in order to correct any

operating problems or possible leaks of smoke into the room.
We recommend making the hood liner in fire-resistant

plasterboard of a 15/20 mm. thickness, with a self-supporting

frame in galvanised profile so as not to put weight on the components

of the cladding (such as wooden beams and marble architraves) that do

not have a load-bearing structure and to make it easy to work in the

event of future anomalies and/or maintenance.