INSTALLATION AND USE MANUAL

Chapter 4

page

21

Installation and assembly

Technical service – MCZ GROUP S.p.A. all rights reserved - Reproduction prohibited

4.5.3. Operation of the control unit MCZ

ON/OFF:

The control unit is turned on/off by pressing the P4 button for a
prolonged time (ON/OFF)
The OFF status is signalled by the lighting of the OFF LED


MAIN MENU:

Setting the THERMOSTATS for the operation of the controlled

outputs:
1. PUMP thermostat: to control the operation of the system pump
2. VALV thermostat: to directly control the solenoid valve or

another application

3. AUX thermostat:

to integrate the gas boiler, solenoid valve

control or another application

How to change them:

 By simply clicking the P1 (MENU) button, the values of the set

Thermostat scroll, as signalled by the flashing of the associated

PUMP / VALV / AUX LED

 To make a change move to the value of the Thermostat to be

changed

 Change the value using the buttons P3(+) and P2(-)
 To save the change wait about 5 seconds or scroll the values

with the button P1(MENU)


Main menu

parameters:

Min.

Default

values

Max

PUMP thermostat

20

40

85

VALV thermostat

20

40

85

AUX thermostat

20

40

85

ALARM FUNCTION:

If the temperature read by the PROBE exceeds the value of the Alarm
Thermostat

A01:

 an acoustic and visual signal is triggered
SILENCE function: the acoustic signal may be deactivated for 5

minutes by pressing any button.

 After this time, if the alarm condition persists, the acoustic signal

is triggered again.

If the PROBE does not work and/or the

Lo

alarm appears:

 an out of range downwards is signalled (Temperature below

0°C): Probe interrupted

If the PROBE does not work and/or the

Hi

alarm appears:

Hi: indicates an out of range upwards (Temperature above

100°C): Probe in short circuit