4.8. THERMAL SAFETY DISCHARGE VALVE FOR CLOSED TANK CIRCUIT

(HYDROTHERM 70V)

4.8.1. Function

The Hydrotherm 70V features a closed tank circuit. In this type of

installation it is compulsory to assemble the thermal discharge valve

(optional accessory). This is a device that limits the water temperature.

In case of boiler overheating it activates an emergency exchanger that

causes the immediate cooling of the water. Its use is regulated by the

standards EN 13229, I.S.P.E.S.L. (file “R” - ed. 2005) and UNI 10412-

2. It also complies with EN 14597 and can be used on systems

complying with EN 12828, concerning solid fuel boilers with non

automatic loading and a power of less than 100 kW.

A THERMAL SAFETY DISCHARGE VALVE FOR CLOSED

TANK CIRCUIT (HYDROTHERM 70V) MUST BE

INSTALLED

4.8.2. Technical specifications

543513