Installation and assembly

Technical service – MCZ GROUP S.p.A. all rights reserved - Reproduction prohibited

4.7.4. Diagram 1 CLOSED TANK (KIT 1 CLOSED TANK)


DESCRIPTION: Fireplace stove without production of domestic hot water.
ACTIONS:

- heating with boiler;
- fireplace stove heating;
- domestic hot water with boiler and heating with fireplace.




1-Hydrotherm fireplace stove

9-Return circuit Ø1” min.

17-Radiator

2-Expansion tank

10-Valve

18-Boiler

3-Control unit

11-Automatic vent valve

19-Thermal discharge valve

4-Manifold 12-Safety

valve 20-Non-return

valve

5-Temperature probe

13-3-way valve

21-Filling unit

6-Circulator 14-Separation

exchanger*

24—Radiator system circulator*

7-Overflow drain

15-Pressure gauge

8-Delivery circuit Ø1” min

16-Hot water

A- Aqueduct


* Not included in the kit. To be purchased separately.