4.7. HYDRAULIC DIAGRAMS

The distance of the hydraulic kit, as stated in the

diagrams below within the speckled area, from the

fireplace stove must not exceed 1 metre.

The following diagrams are to be used only as a guideline.

For proper connection, follow the notes and the instructions

of the plumbing and heating installer, in compliance with

regulations in force.

4.7.1. Diagram 1 OPEN TANK (KIT 1 OPEN TANK)


DESCRIPTION: Fireplace stove as the only heat source with production of domestic hot water (DHW).
ACTIONS:

- fireplace stove heating;
- domestic hot water with fireplace.


1-Fireplace stove

6-Delivery circuit

11-Flow switch

2-Open expansion vessel with float

7-Return circuit

12-Domestic water

3-Control unit

8-Automatic vent valve

13-Radiator

4-Temperature probe

9- 3-way valve

A- Aqueduct

5- Circulator

10 - Domestic hot water exchanger

TA-Room thermostat