MCZ Hydrotherm 70 User Manual

Page 38

Advertising
background image

INSTALLATION AND USE MANUAL

Chapter 5

page

38

Operation

Technical service – MCZ GROUP S.p.A. all rights reserved - Reproduction prohibited

Slowly fill the fireplace stove and the system only using

the open expansion tank (if included) through the

natural fall of water;

With the installation with the tank closed, fill the system

directly from the mains, setting a pressure, when cold,

of 1-1.5 bars and discharging any air bubbles in the

boiler and on the system.

Never light the fire if the system is not full of water; the

structure may be damaged.

While filling, open all the vents of the radiators and

those of the system; vent the air in the system that may

obstruct the circulation of water.

On the control panel or control unit set the start

temperature of the pump (see the instructions of the

control panel).

Place wood in small pieces that is well dried (humidity

15/20%). Light the fire without excessively overheating

the structure during the first lighting. Any odours from

manufacturing residue and/or evaporation will form the

first time lighting occurs, and will disappear after a

lighting at full power has occurred a few times.


Make sure you have read and completely understood the contents of

this instruction booklet.
Remove any components which might burn from the fireplace stove

and door (various instructions and adhesive labels).
Remove the stickers from the ceramic glass or the high temperature

could melt them and irreparably damage the glass. In this case, the

MCZ warranty does not cover the glass.
The HYDROTHERM fireplace stove can be placed in a corner or along a

wall. You can customize with MCZ claddings or install them during

construction with materials that are resistant to high temperatures.

THE CLADDING MAY ONLY BE INSTALLED AFTER

HYDRAULICALLY AND ELECTRICALLY CONNECTING

THE FIREPLACE STOVE AND HAVING TESTED ITS

FUNCTION AND HYDRAULIC SEAL


The fireplace stove and the parts of the cladding must be attached to

one another without coming into contact with the steel

structure to prevent transmission of the heat to the marble and/or

stone, and to allow normal thermal dilation. Use care with wood

finishes such as crossbeams or shelves.
It is advisable to create the hood of the cladding with plasterboard

panels. It is worthwhile to provide for an airtight inspection grille to

access the probe in case of malfunction.