4. INSTALLATION AND ASSEMBLY

IMPORTANT!
The fireplace stove must be installed and connected

to the smoke duct only by a specialized technician, so

that all local and national regulations are complied

with.
Installation must in any case by carried out in

compliance with UNI 10683.

When the fireplace is unpacked, check for perfect operation of all

its parts or any damage which may have occurred during

shipping. The retailer or the carrier must be immediately

informed of any damage.
If the fireplace stove is installed in a place that is difficult to reach, its

weight can be reduced by removing the internal parts that make up the

fire box. However, be sure to put all of the parts back in place.

This operation is to be carried out only by specialized

personnel.
MCZ shall not be held liable if the preceding warning is not

complied with.

4.1. PREPARATION AND UNPACKING

Open the packaging, remove the stove unit from the pallet and position

it in the chosen location, taking care that its position complies with the

above instructions.

The fireplace stove must always be kept VERTICAL

while moving and only using hand trucks. Do not

drag the unit as this may damage the support feet.

Be especially careful that the door and its glass are protected from

mechanical collisions that could jeopardise their integrity.
Moving the product must be done with care. If possible, unpack the

fireplace stove in the area where it is to be installed.
The materials which make up the packaging are not toxic or harmful,

so no special procedures for disposal are required.
The final user must store, dispose or recycle packaging material in

accordance with local regulations.

4.2. POSITIONING

The HYDROTHERM fireplace stove can be placed in a corner or along a

wall. You can customize with MCZ claddings or install them during

construction with materials that are resistant to high temperatures.
The fireplace stoves are self-supporting single-piece units that simplify

installation and do not require any additional support.
Always evaluate the structural condition of the surface which

will take the weight, and always leave a minimum 5 cm

airspace between the stove and any walls.
Install dry the fire bed of the cladding leaving an opening of 1 cm

for the insulation.