Installation inspection of the reference machine

5710 A

1

Wascator FOM 71 CLS

Installation inspection of the
reference machine

Before carrying out any major test series inspect
the installation and check the following terms:
• The machine must be installed on a level

base. The following clearances are recom-
mended in order to facilitate calibration:
At least 500 mm between the machine and
the wall behind and min. 50 mm on both
sides of the machine whether installed next to
the wall or other machines.

• Check the levelling of the machine. The verti-

cal difference from corner to corner of the top
lid shall not exceed 5 mm. If not adjust the
feet of the machine.

• The machine shall be connected using the

supplied Y hose or using two single hoses.

• The water hose and power cable must hang

freely between the machine and wall in order
to prevent disrupting the reference machine
scale system.

• Make sure that the drain installation is made

according to the information on next page.
Observe the required air gap in the drain sys-
tem.

50 mm

500 mm