Flow meter calibration – Electrolux FOM 71 CLS User Manual

Page 68

Advertising
background image

18:2

Flow meter calibration

o If amount of water is not correct adjust the K-factor until the correct amount

is achieved.

o Be sure no other machine connected to the same water line is filling water at

the same time the calibration is done.

• Procedure B:
If a high quality and resolution calibrated laboratory flow meter is connected in se-
ries with the reference machine flow meter, the following procedure may be imple-
mented instead:

o Select the Cotton 60°C program (or any other IEC cotton program).
o Start the program without load.
o Pause the program after first fill.
o Read the laboratory flow meter and compare with the 26 litres the reference

flow meter is to supply.

o If the amount of water is incorrect, adjust the K-factor until the correct

amount is achieved.

o Rapid advance the program to its end.
o Be sure no other machine connected to the same water line is filling water at

the same time the calib