Adjustment of temperature, speed and water – Electrolux FOM 71 CLS User Manual

Page 31

Advertising
background image

7:5

FUNCTION

DEFAULT
VALUE

EXPLANATION

TEMPERATURE CONTROL OF
WATER

Y

If set to Y and using hot and cold water supply the
hot and cold water is pulsed so the inlet water tem-
perature does not exceed the set temperature.

TEMPERATURE IN ºC

Y

Temperatures shown in centigrade. If N is set the
temperature shown will be in Fahrenheit.

REPEATED PROGRAM MODE
QUESTION

N

If set to Y a switch between standard and advanced
programming can be made before each sequence.
FOM 71 CLS shall always be programmed in advan-
ced mode.

LOCKED STANDARD WASH
PROGRAMS

N

If N the user has access to programs 991 -999. IN
FOM 71 CLS these programs are the start up and
check programs.

LEVEL QUICK COOL DOWN

80

If sequence COOL DOWN is used this value defines
the level increase of cold water if the Quick Cool
down function is activated.

LEVEL UNBALANCE

0

If set to a value other than zero the machine fills the
drum to selected level at an unbalance stop before
next attempt to distribute. For FOM 71 CLS the value
shall be 0

LEVEL LOW

0

Set level for low level question in standard program-
ming mode. Not used with FOM 71 CLS

LEVEL MEDIUM

0

See above (medium level)

LEVEL HIGH

0

See above (high level)

MIDDLE TEMPERATURE COOL
DOWN

70

Breaking point in the cool down sequence where the
temperature controlled cool down (4 ºC/min) ends
and the unmonitored part of the cool down sequence
starts.1 step = 1ºC

DEFAULT MOTOR ON TIME

12

A default value for the motor on time. This value only
used during certain restarts after for example unba-
lance breaks. 1 step = 1 sec

DEFAULT MOTOR OFF TIME

3

Default value for the motor off time: Only used as
above. 1 step = 1 sec

FLUSH DELAY TIME

10

Delay time for the flushing of water when liquid de-
tergent injection pumps are used. 1 step = 1 sec

FLUSH ON TIME

6

Flushing time for the water after the flush delay time.
1 step = 1 sec

BUZZER ON BUTTON

N

If Y a beep will occur each time a front panel key is
pressed.

MAX FILLING TIME

60

Max filling time before an error message occur if not
level/amount of water has been reached. 1 step = 10
sec

MAX HEATING TIME

60

Max heating time before an error message occurs if
the temperature has not increased a specific number
of degrees. 1 step = 10 sec

Adjustment of temperature, speed and water

Table 1: Parameters in Settings 1

Advertising
This manual is related to the following products: