Flow meter: Setting of the correct amount of water

FOM 71 MP-Lab

Flow meter: Setting of the correct amount of water

(All references in this document refers to ELS Document 438 9041-07
Installation of the flow meter control FOM 71 MP-Lab. See Appendix 1)
In IEC 60456 Ed 5 the amount of water levels programmed into the flow
meter shall be set according to table D.3 in the standard.

Program

Set value A1 (Litre)

Set Value A2 (Litre)

Cotton 85 °C

26

18

Cotton 60 °C

26

18

Cotton 40 °C

26

18

Synthetics/Blends 60 °C

22

4

Synthetics/Blends 40 °C

22

--a

Wool 40 °C

26

--a

Cotton 30 °C

26

18

Cotton 20 °C

26

18

NOTE:
a: No set value for A2 needed

IEC 60456 Ed5 Table D.3

Procedure for programming new set values into the flow meter:

• Follow the programming given in the Installation manual for the flow

meter page 6 to 9.

• Go through the complete configuration procedure and set A1 and A2

(page 8 in the Installation manual) to the desired values.

• Control that the flow meter is delivering the correct amount. If a devia-

tion correct with the K-factor (See Chapter 18 Flow