Calibration of level control system – Electrolux FOM 71 CLS User Manual

Page 14

Advertising
background image

4:2

Calibration of level control system

1

CLS 7.jpg

2

IMG 0012.jpg

Calibration of level control system

The level control system can be calibrated both individually and manually.
Calibration starts at the bottom of the inner drum and can go up to 250
mm from that point.
A ruler is supplied with the machine with which the water level above the
inner drum can be read.

• Place the ruler on the bottom of the inner drum, equidistant between two

lifters and front and rear gables. Rotate the drum so that the ruler is fully
vertical and ensure that the three pins of the ruler fit in the holes of the inner
drum.

• Push the scale to the bottom of the drum and tighten the nuts.

• Close the door.