Calibration of the scale system – Electrolux FOM 71 CLS User Manual

Page 24

Advertising
background image

6:2

Calibration of the scale system

Installation of speed sensor

A speed sensor can be attached to the end of

the drum shaft. In order to be able to attach the

sensor, a hole can be made in the back panel

of the machine. A diameter less than 60 mm

will not affect the performance of the machine.

(Ventilation holes may change the air tempera-

ture inside the machine, which may also affect

water temperature.)

External weight sensing signal

An external signal may be obtained from the

weight control system. On distribution card B

(located on the right side panel in the rear con-

nection box), there are two outputs (X78:1 and X

78:2), which are for the weight signal. The loca-

tion of X78 is shown in the diagram of distribu-

tion card B below.


Electrical installation must be carried out
by an authorized personnel

5331

1

View of rear connection box

Japan only

A

B

A B