FUNCTION

DEFAULT
VALUE

EXPLANATION

SPEED CALIB. LOW RANGE IN %
From software 1.8 and machine serial
number 052089296

1000

Will change the drum speed in the low speed interval
≤ 300 RPM. The default value is a ratio value and a 1
unit change will change the ratio 0.1%
Thus 956 will mean 95.6% of original speed and
1050 105% of original speed.

SPEED CALIB. HIGH RANGE IN %
From software 1.8 and machine serial
number 052089296

1000

Will change the drum speed in the high speed inter-
val > 300 RPM. The default value is a ratio value and
a 1 unit change will change the ration 0.1% in the
same way as for LOW RANGE.

SHOWED SPEED CALIB. LOW'
From software 1.8 and machine serial
number 052089296

1000

Corrects the speed showed in display to actual
speed
Will change the showed display speed in the low
speed interval ≤ 300 RPM. The default value is a
ratio value and a 1 unit change will change the ratio
0.1% Thus 956 will mean 95.6% of original displayed
speed and 1050 105% of original displayed speed.

SHOWED SPEED CALIB. HIGH
From software 1.8 and machine serial
number 052089296

1000

Corrects the speed showed in display to actual
speed
Will change the shown display speed in the high
speed interval > 300 RPM. The default value is a ratio
value and a 1 unit change will change the ratio 0.1%
in the same way as for CALIB. LOW.

BACKLIGHT

30

Controls the time the display shall be illuminated in
seconds. 1 step = 1 sec.Max value 254 seconds.
Value 0 means display always illuminated.