To save and read the timer file, To enable the timer, To enable the timer -26 – RIGOL DP832A User Manual

Page 80

Advertising
background image

RIGOL

Chapter 2 Front Panel Operations

2-26

DP800A User’s Guide

To Save and Read the Timer File

You can store the timer parameters edited manually or using the templet in internal

or external memory and recall them when required.

1. Save

After editing the timer parameters, press Save to enter the store and recall

interface. The file type is fixed at “*.rtf” and please save the file according to the

introduction in Save.

2. Read

Press Read to enter the store and recall interface. The file type is fixed at “*.rtf”

and please read the desired file according to the introduction in

Read. Users

can edit the timer file read.


To Enable the Timer

After setting the timer parameters, return to the timer and delayer interface (as

shown in Figure 2-1). Press Timer to enable the timing output. The timing output

interface is as shown in the figure below.

Figure 2-3 Timing Output Interface

Tip
 Enabling the timer will change the output value of the channel; make sure

that the change in the output value will not affect the device connected to

the power supply before enabling the timer.

 The timing output is valid only when both the timer and the channel output

are turned on.

 When the timer is enabled, the timer parameters cannot be modified and

Delayer is grayed out and disabled.

Advertising