Check the amperage of the receptacles used referring to TABLE 1, and be sure not to take a
current exceeding the specified amperage.

Be sure that the total wattage of all appliances dose not exceed the rated output of the gen-
erator.

TABLE 1

NOTE :
When the no-fuse breaker turns off during operation, the generator is over loaded or the appli-
ance is defective. Stop the generator immediately, check the appliance and / or generator for
overloading or detect and have repaired as necessary by Robin dealer or service shop.

The duplex 120V receptacle is protected by a GFCI (Ground Fault Circuit Interrupter).
GFCI shuts off the output current from the duplex 120V receptacle when a ground fault
occurs in the generator or the appliance.
Please note that other receptacles are not protected by GFCI.

CAUTION

up to 30A

up to 30A

up to 20A

NEMA

5-20R

NEMA

L5-30R

NEMA

L14-30R

NEMA

5-20P

NEMA

L5-30P

NEMA

L14-30P

GFCI (Ground Fault Circuit
Interrupter) Receptacle, duplex

(REC1)

Locking Receptacle
(REC2)

Locking Receptacle
(REC3)

Style

Ampere

Receptacle

AC plug

Description

up to 30A

NEMA

L21-30R

NEMA

L21-30P

up to 50A

Locking Receptacle
(REC4)

Locking Receptacle
(REC5)