(4) CIRCUIT TESTER

Used for measuring resistance, etc.

(5) MEAGER TESTER

Used for measuring generator insulation
resistance.
Select one with testing voltage range of
500V.

7-2 AC OUTPUT MEASURING

SWITCH

LOAD

TO AC RECEPTACLE

F

A

~

V

~

Use a circuit above for measuring AC output. A hot plate or lamp with a power factor of 1.0
may be used as a load. Adjust the load and rpm. and check that the voltage range is as speci-
fied in the following table at the rated amperage and rated rpm.