Subaru Robin RGV12100 User Manual

Page 16

Advertising
background image

13

GFCI RECEPTACLE

After starting the engine, check the GFCI for proper functioning by the following test procedure.

Push blue TEST button, The red RESET button will pop out exposing the word TRIP. Power
is now off at the outlets protected by the GFCI, indicating that the device is functioning prop-
erly.

If TRIP dose not appear when testing, do not use the generator. Call a qualified electrician.

To restore power, push RESET button.

If the RESET button pops out during operation, stop the generator immediately and call
a qualified electrician for checking generator and the appliances.

WARNING

CONNECTING TO DOMESTIC CIRCUIT (HOUSE WIRING)

This generator is neutral grounded type.
If a generator is to be connected to residential or commercial power lines, such as a
stand-by power source during power outage, all connections must be made by a
licensed electrician.
Failure in connection may result in death, personal injury, damage to generator, dam-
age to appliances, damage to the building's wiring or fire.

WARNING

(a) When connecting a Robin generator to a house wiring, generator output power must be taken

from the 240V-4P receptacle.

(b) Install a transfer switch.

A transfer switch must be installed to transfer the load from the commercial power source to
the generator. This switch is necessary to prevent accidents caused by the recovery from
power outage. Use a transfer switch of the correct capacity.
Install transfer switch between the meter and the fuse or AC breaker box.

If the neutral wire of house wiring is grounded, be sure to ground the ground terminal
of the generator, Otherwise an electric shock may occur to the operator.

CAUTION

Advertising
This manual is related to the following products: