Tc menu – Sony X85K 50" 4K HDR Smart LED TV User Manual
Page 44
44
Detailed Menu Description
C
h
a
p
te
r 5
M
e
nu
It
em
s
TC Menu
The TC menu allows you to set all of the items related to
time codes from a single menu.
Button
Indication
Setting
Target
[F1]
TCG SRC
Selects whether to synchronize the internal time code generator with the external
signal.
preset
ext-LTC
SDI-LTC
SDI-VITC
In
[F2]
REGENE
Selects the signal to regenerate when the time code generator is in regenerate
mode.
TC & UB:
Regenerates both the time code signal and user bit signal.
TC:
Regenerates only the time code signal.
UB:
Regenerates only the user bit signal.
In
[F3]
RUN
Selects the running mode of the time code generator.
Free:
The time code advances when the power is on regardless of the unit’s
operation mode.
Rec:
The time code advances only during recording.
In
[F4]
DF/NDF
Selects the drop frame mode of the time code generator or timer counter.
DF:
Drop frame mode
NDF:
Non-drop frame mode
Notes
• This setting is only enabled when the frame frequency of the unit is 29.97 Hz or
59.94 Hz.
• This setting is only valid when
[F1]
(TCG SRC) is set to “preset.”
I/O
[F5]
TM SEL
Selects the time data to display on the display. To switch between VITC and LTC,
press the
[F10]
(TCR SEL) button.
TC
UB
TM1
TM2
I/O
[F7]
TM RESET
Resets the time counter.
I/O
[F8]
TM SET
Inputs time data.
I/O
[F9]
TM HOLD
The time counter is temporarily stopped while the button is pressed.
Out
[F10]
TCR SEL
Sets the value read by the time code reader.
LTC
VITC
Out
ALT/
[F3]
TC OUT
Sets the time code that is output from the TIME CODE OUT connector during
recording when the internal time code generator is set to a mode for regenerating
the playback time code.
Through:
Outputs the time code signal input from the TIME CODE IN connector as
is.
Regene:
Regenerates the time code signal input from the TIME CODE IN
connector before outputting it.
In
ALT/
[F4]
TM DISP
Sets whether TM1 is in 12-hour display mode or 24-hour display mode.
Note
When ±12H is set, the tens digit of the hours value is dropped.
+–12H
24H
I/O