Pressure Systems, Inc. Model 9046 User’s Manual

Page 4

www.PressureSystems.com

Precision

Temperature

Device

Jumper sockets for thermocouple/resistance
mode selection (jumper = thermocouple)

Sockets for temperature transducer

Sockets for
resistance
excitation

Universal SCM

Non

Nonun

Non-Universal SCM

Sockets for temperature transducer

Sockets for
resistance
excitation

Precision

Temperature

Device

Figure 1-2: Signal Conditioning Module (SCM)

1.1.3.2 Open Circuit Detection

The SCM, without the open circuit detect feature, is used where an electronic engine control
package is used which requires a high degree of isolation from ground in order to reduce offsets
in the temperature signal. This unit will handle thermocouples only and has no jumper.

2.0 Setup Instructions

Use the procedures in this section to set up a Model 9046 module.