Pressure Systems, Inc. Model 9046 User’s Manual

Page 48

www.PressureSystems.com

Note

NUSS automatically creates a default Run State 0 for every module
that uses its Run function. This run state uses the above sub-
command to configure three (3) "unbounded" autonomous data
streams that the module will deliver concurrently at various rates to
the host:

• Stream 1 contains Primary Transducer E.U. data

(Temperature/Resistance) only for every channel and
repeats every 1/2 second.

• Stream 2 contain a Thermal Alarm Prefix and Primary

Transducer Counts and Volts data for every channel, and
repeats every 2 seconds.

• Stream 3 contains Other (UTR/Source Voltage) Transducer

data (in E. U., Counts, and Volts) for every channel and
repeats every 7.5 seconds.

The Run function will acquire all the data defined in the Run State,
but will display only the data in the arriving streams that match the
form’s currently configured Display requirements (called its Display
Set). If a user requires other stream contents or rates, these can
be configured (as Run States 1-9) using the NUSS Run State
Editor. Any run-state can be assigned to the Run form of each
module.