Pressure Systems 9046 User Manual

Page 58

Advertising
background image

Pressure Systems, Inc. Model 9046 User’s Manual

Page 52

www.PressureSystems.com

Example:

Stop all the streams configured in the previous example:
"c 02 0"
Read response:
"A"

Note

NUSS uses this sub-command to stop the acquisition of data on
each Run form when that form exits, or when the [Acquire] button
on the form is clicked once. Clicking the [Acquire] button again
restarts the current Run State’s acquisition cycle "completely" by
sending another set of stream initialization sub-commands (i.e., ’c
00’ and ’c 05’ for each configured stream) followed by a Start All
Streams (’c 01’) command. This more lengthy re-init./re-start
sequence insures that each stream is restarted at sequence # 1.
The user can also "pause" the streams by clicking any of the green
boxes that display the current stream sequence numbers. This
causes a Stop All Streams (’c 02’) sub-command to be sent, and
the green boxes turn yellow to indicate a "pause". Clicking any of
the yellow boxes again will “resume” the streams by sending a
single Start All Streams sub-command. This causes the boxes to
turn green again and resume incrementing the sequence counters
where they left off. Of course, any "bounded" stream, that may
eventually expire, is not restarted by this simpler "resume" process.

Advertising