Pressure Systems 9046 User Manual

Page 8

Advertising
background image

Pressure Systems, Inc. Model 9046 User’s Manual

Page 2

www.PressureSystems.com

1.1.2 Physical Description

Figure 1-1: Exploded View of Module

The Model 9046 temperature scanner is housed in a rugged machined aluminum case. The
case is splash proof and finished to allow installation in a turbine engine test cell environment.
Sensors can be connected to the Model 9046 in two different wiring configurations:

• Top panel thermocouple mini-jacks, or MIL style circular connectors (RTDs, thermistors,

etc.)

• Side entry for direct connection. (Crouse Hinds CGB box style strain relief on end panel).

The direct wire connection is the most economical, and the most accurate, as it eliminates one
thermocouple junction and its attendant potential for errors.

The Model 9046 has the same mounting footprint as the PSI NetScanner family of pressure
scanners. It is approved for operation in an ambient temperature environment from –30 to +70
degrees Centigrade.

Advertising