50

Self Test

Status

The autoloader is executing the power-on self-test.

51

SemiLoaded

Status

Although a cartridge is in the drive, it has not been loaded
(“semi-loaded” status).

52

Stray Tape:
Insert Empty
Mag

Information

The autoloader does not contain a magazine for taking a
cartridge from the drive. Insert a magazine with an empty
slot.

53

Tape Fault

Error

Blinking

The drive contains a defective cartridge.
Use a new DDS-compliant tape.

54

Tape Full

Error

On

A read, space, write, or write file mark command detected
an unexpected EOP (For a read operation, this message
sometimes indicates that data extends over the current and
the succeeding cartridges).

55

Tape has DC
Data

Error

On

Although compressed data was detected when a read
command was executed, the drive settings do not
correspond with decompression of data (The drive is
factory-set to compressed mode. If it is unchanged, this
error cannot occur).

56

Tape Position
Lost

Error

Blinking

A write, read, space, or rewind command terminated
abnormally. The current tape position is immediately after
the erroneous data area. Reset the data position, and retry.

57

Tape Stuck

Error

Blinking

A cartridge is stacked in the drive. Attempt to forcibly eject
the cartridge. If the error still recurs, contact the store where
you bought the system or call the maintenance personnel.

58

Unloading

Status

• The drive is unloading a cartridge.
• The drive is ejecting a cartridge and returning it to the

magazine.

59

UpgradeErr

Error

Blinking

Upgrading firmware failed. Check the SCSI cable for
connection, and retry.

60

Worn Media

Error

Blinking

A high error ratio was detected during a write operation.
This indicates that the service life of the cartridge is coming
to an end. Copy the data in the cartridge to a new one, and
discard the old one.

61

Write x.y

Status

The drive is writing data to tape (“x.y”:1 is the accumulated
compression ratio since power-on or since the compression
ratio was cleared).

62

Write Protected
Tape

Error

Blinking

When a write, write file mark, or erase command was
executed, processing could not be completed because the
cartridge was write-protected. Cancel the write protection,
and retry.

63

Write Fail

Error

Blinking

A write, write file mark, or erase command failed. Use a new
cartridge.