During normal operation, the control automatically monitors the
oil level in the vat. If the control senses the oil level too low, the
unit automatically pumps oil from the JIB into the vat to keep
the oil at the proper level.

Manual Top-Off
If the oil level is a little low, oil can be added to the vat at any time
from the JIB to raise the oil level to the proper level by following the
steps below. This procedure is NOT to be used to fill an empty vat

1.

Press and hold

(eitherone-full vat) until display shows

“*FILTER MENU*”, along with “1.EXPRESS FILTER”.

2.

Press

5 times until “6.FILL FROM JIB” shows in

the display.

3.

Press

√√√√√ button and display shows “*PUMP” and “EXIT”.

4.

Press and hold

√√√√√ button and display shows “FILLING” and

the oil is pumped from the JIB to the vat.

5.

Once frypot is full, release

√√√√√ button and display returns to

“*PUMP” and “EXIT”. Press X button twice to return to
normal operation.

When selecting a product, if “XXX XXX” shows in the display, the
setpoint temperature is not correct for this product.

To change the setpoint temperature for the desired product:

1.

Press product button, for ex: (FRY).

2.

Display shows “XXX XXX”.

3.

Press and hold a timer button

or for 5

seconds and then “FRY” shows in display.

4.

Allow oil temperature to reach setpoint temperature before
dropping product.

1.

Control displays “JIB IS LOW” and an alarm sounds.

2.

Open right door and pull JIB from unit. Pull the cap from top
of JIB and discard empty JIB and replace with full one.
Figure 1

Model EEG-141 (single-well) see next section.

3-8. SELECTING A PRODUCT

WITH A DIFFERENT
SETPOINT

3-9. REPLACING THE JIB

Figure 1

3-7. OIL GUARDIAN™

(Auto Top-Off)