Henny Penny EVOLUTION ELITE EEG-141 User Manual

Page 44

Advertising
background image

Model EEG-141, 142, 143, 144

3-23

609

3-18. CHECK/REPLACE FILTER

DRAIN PAN O-RINGS

To prevent oil leaking, and to keep filtering process operating
properly, the filter drain pan o-rings should be inspected for nicks
and tears at least every 3 months. Figure 1

1. Open the door, lift-up on the drain pan stop and pull-out the

filter drain pan assembly, using the handle on the drain pan.
Figures 2 & 3

This pan could be hot! Use protective cloth or glove, or
severe burns could result.

2. Visually check the 3 o-rings on the tube of the filter drain pan

for any cracks or breaks and replace if necessary.

3. To replace o-ring, use a small, flat-bladed screwdriver, pry up

on the o-ring and pull off of end of tube. Roll new o-ring into
notch on tube. Before pushing the filter drain pan back into
position, lubricate the o-rings on the filter tube with fresh, cold
oil.

Figure 1

Figure 2

Figure 3

Figure 4