7-2. ERROR CODES

“E-20-A”

• Pressure Switch

• If fan is not running, have pressure switch checked; should be

“FAN SENSOR

failure

open circuit if no air pressure

STUCK

• wiring problem

• If fan is running, wiring error, or relay on I/O board closed

CLOSED”

• I/O board failure

“E-20-B”

• Pressure Switch

• Press power button to vat off and back on again, if E-20-B

“NO DRAFT”

failure/hose loose

persists, have pressure switch checked; should be open circuit

“CHECK

• Draft Fan failure/

if no air pressure; make sure hose is connected to fan and

FAN”

low voltage

pressure switch

• Flue or hood

• Have draft fan checked; low voltage going to fan

obstructions

• check the fryer flue and hood system for obstructions

“E-20-D”

• Failure to ignite/

• Press power button to vat off and back on again, if E-20-D

“IGNITION”

no flame sense

persists, check gas line connections; check gas shut-off valve;

“FAILURE”

have ignition module checked; gas valve checked; flame sensor
gap checked; gas valve and ignition module wiring checked

“E-21”

• Slow heat recovery

• Have a certified service technician check the fryer for correct

voltage to the unit; have heat circuit checked; have unit
checked for loose or burnt wire

“E-22”‘NO

• Burner not igniting

• Have gas valve and heat circuit checked

HEAT” “CHECK

GAS VALVE”

“E-41”, “E-46”

• Programming

• Press power button to vat off and back on again, if any

failure

of the error codes, have the controls re-initialized; if error code
persists, have the control board replaced

“E-47”

• Analog converter

• Press power button to vat off and back on again, if “E-47”

chip or 12 volt

persists, have the I/O board, or the PC board replaced; if

supply failure

speaker tones are quiet, probably I/O board failure; have the
I/O board replaced

“E-48”

• Input system error

• Have PC board replaced

“E-54C”

• Temperature input

• Turn switch to OFF, then back to ON; have control PC board

error

replaced if “E-54C” persists

“E-60”

• AIF PC board not

• Press power button to vat off and back on again if “E-60”

communicating with

persists, have the connector between the PC boards checked;

control PC board

replace AIF PC board or control PC board if necessary

DISPLAY

CAUSE

CORRECTION

7-4