Model EEG-141, 142, 143, 144

7-2. ERROR CODES

In the event of a control system failure, the digital display shows an
error message. The message codes are shown in the DISPLAY
column below. A constant tone is heard when an error code is
displayed, and to silence this tone, press any button.

DISPLAY

CAUSE

CORRECTION

“E-4”

• Control board

• Turn switch to OFF position, then turn switch back to ON;

overheating

if display shows “E-4”, the control board is getting too hot;
check the louvers on each side of the unit for obstructions

“E-5”

• Oil overheating

• Turn switch to OFF position, then turn switch back to ON;
if display shows “E-5”, the heating circuits and temperature
probe should be checked

“E-6A”

• Temperature

• Turn switch to OFF position, then turn switch back to ON;

probe open

if display shows “E-6A”, the temperature probe should be
checked

“E-6B”

• Temperature

• Turn switch to OFF position, then turn switch back to ON;

probe shorted

if display shows “E-6B”, the temperature probe should be
checked

“E-10”

• High limit

• Press the red reset button under the right side of the controls;
if high limit does not reset, high limit must be replaced

“E-15”

Drain switch

Make sure drain knob is completely pushed-in; if E-15 persists,
have drain switch checked

“E-18-A”

• Left level sensor open • Turn switch to OFF position, then turn switch back to ON; if

“E-18-B”

• Right level sensor open display still indicates a failed sensor, have the connectors

“E-18-C”

• Both level sensors open checked at the control board; have sensor checked & replace if

necessory