Item

Description

Syslog Server IP
address

IP address of a syslog server to send syslog
messages to. If zero (0.0.0.0) or not specified,
syslog messages are disabled.

Syslog Maximum
Messages

The number of syslog messages that can be
sent by the HP Jetdirect print server on a
per-minute basis, from 0 to 1000. This
parameter helps to control the syslog file size.
The default is 10 messages per minute. If 0,
the number of syslog messages is not
restricted.

Syslog Priority

A method for filtering syslog messages that
are sent to the syslog server. The range is 0
through 8, with 0 the most specific and 8 the
most general. Only messages that are lower
than the specified filter level (or higher in
priority) are reported. The default is 8,
messages of all priorities are sent. If 0, all
syslog messages are disabled.

Syslog Facility

A code used to identify the source facility of
a message (for example, to identify the source
of selected messages during troubleshooting).
By default, the HP Jetdirect print server uses
LPR as the source facility code, but local user
values of local0 through local7 can be used to
isolate individual or groups of print servers.

Typical logfile entries of syslog messages:

Oct 22 08:10:33 jd08 printer: error cleared
Oct 22 15:06:07 jd04 printer: powered up
Oct 22 15:07:56 jd04 printer: offline or
intervention needed
Oct 22 15:08:58 jd04 printer: error cleared
Oct 24 17:52:27 jd37 printer: powered up
Oct 24 18:28:13 jd37 printer: printer is
disconnected
Oct 24 18:37:46 jd07 printer: error cleared
Oct 24 18:38:42 jd37 printer: powered up
Oct 25 07:50:16 jd04 printer: toner/ink low