Lamp Life Limit

Use this menu option to display the warning message Lamp Life Error when the current lamp
hours reach the rated lamp life. When the

LAMP LIFE LIMIT

parameter is enabled, the fixture

tracks the number of hours the lamp is on. At 650 hours, it displays an error message. At 710
hrs., the lamp shuts off, and the fixture will not strike until the lamp is replaced and the lamp
hours are reset to 0. See Replacing the Lamp on page 42 and Lamp HR/Strike Reset on page 31.

To enable the

LAMP LIFE LIMIT

parameter:

1. Press the Menu button to unlock the menu system or to move back up the system to the top

level menus.

2. Using the left and right arrows on the Center button, scroll through the top level to

SET

PARAMETERS MENU

and press the Enter button to select.

3. Using the left and right arrows on the Center button, scroll to

LAMP LIFE LIMIT

.

4. Using the up and down arrows on the Center button, choose the

ENABLE

option and press

Enter to select.

Data Loss Timeout

Use this menu option to determine how the fixture will react in the event of DMX data loss. Set
the shutter to stay open until shutdown or to close one second after data loss.

To set the

DATA LOSS TIMEOUT

:

1. Press the Menu button to unlock the menu system or to move back up the system to the top

level menus.

2. Using the left and right arrows on the Center button, scroll through the top level to

SET

PARAMETERS MENU

and press the Enter button to select.

3. Using the left and right arrows on the Center button, scroll to

DATA LOSS TIMEOUT

.

4. Using the up and down arrows on the Center button, choose

LONG

to keep the shutter open

until shutdown, or

SHORT

to close the shutter 1 second after data loss and press the Enter

button to select.