51

Calibrate the flags

6. Power up the fixture. Unlock the Menu system by pressing Menu button for a few seconds

until the display goes to the 2-line format.

7. Use the left and right arrows

to scroll to the Test option. Press Enter to select.

8. Use the up and down

arrows

to scroll to

SETUP

MOTORS

. Press Enter to

select. Use arrows to scroll
to

YES

and press Enter to

select. Flags will energize
against the standoffs.

9. Using a 2 mm hex key,

loosen the set screw at the
base of the flag.

10. Adjust each flag vertically to

the tickmark on the inside
standoff.

11. Remove the service harness and re-attach the connectors to the 2-phase driver board.

12. Reinsert the bulk head and replace the two 4M socket caps.

13. Home the fixture and test flags. Make sure they are not hitting when fully closing from the

console or the menu system.