CHAPTER 4

Fixture Programming

SHOWGUN

®

User Manual

39

Control Settings

The Control parameter activates certain Fixture functions. To access all SHOWGUN

®

Control

settings (except for Pan & Tilt MSpeed Off), first select a control channel value, then set the
Shutter channel to “0.”

NOTE: The Control channel should not be crossfaded.

DMX Control Setting

Description

0-9

Safe

Disables all Control settings for normal operation.

10-19

Pan & Tilt

MSpeed Off

Sets Pan & Tilt MSpeed to ignore MSpeed settings. The Control
channel should not be crossfaded.

20-28

Display Off

Sets display to off.

Set Shutter parameter = 0
to access these control
options

40-48

Display Bright

Brightens the display characters.

60-68

Home

Remotely homes the fixture.

80-88

Lamp On

Remotely restrikes the fixture’s lamp.

90-98

Lamp Off

Remotely extinguishes the fixture’s lamp.

120-130

Shutdown

Remotely deactivates the fixture. When a fixture is shut down, the
lamp is extinguished, power to the motors is disabled, and the LED
display reads “

SHUT DOWN

”. If a fixture is in shutdown mode, you must

home the fixture to bring it back into operation.

131-140

Outrig Mode

Insures uninterrumpted movement of pan and tilt for fixtures side
mounted or in acute angular positions.

Note: Because this is a DMX mode, it will not persist in the fixture.

Side Mounting and Angular Mount by Moving Truss

To insure uninterrumpted movement of pan and tilt use "Outrig mode". Operating a fixture in the
Outrig mode will slow Pan and Tilt motion. Setting the Outrig mode in the Control parameter of
your DMX controller lets you turn the option on or off as needed during a production (when
trusses move to an accute angular position, for example).

Note: Because this is a DMX mode, it will not persist in the fixture.