Flag calibration example – High End Systems SHOWGUN User Manual

Page 62

Advertising
background image

CHAPTER 5

Maintenance and Troubleshooting

50

SHOWGUN

®

User Manual

5. Push the lens into the fixture

6. Reattach the retaining clips on the lens shaft.

Flag Calibration Example

This example shows you how to recalibrate the dimmer flags:

2. Remove the two M4 socket

caps and slide the Lower
bulk head out of the fixture.

3. Loosen two captive screws

to remove electronic
housing cover over the
display panel and take out
the two service harnesses
located on the back side of
the display panel.

4. Locate the 2-phase board

that controls the dimmer
motors. Disconnect the M1
and M2 for the two DIM flags
on Board 2 (the lower front
board of the 4-board bracket
inside the fixture.

5. Connect one end of a

harness to a flag of the
dimmer motor and the other
to the corresponding header
on the 2-phase board (see
page 49). You can connect
and home one flag or a pair
of flags at the same time.

Connect dimmer flag motors directly to 2-phase driver

1. Detach header from motors

powering the two DIM flags
on the Lower bulk head.

Advertising