Replacement fuses, Replacing the lamp – High End Systems SHOWGUN User Manual

Page 54

Advertising
background image

CHAPTER 5

Maintenance and Troubleshooting

42

SHOWGUN

®

User Manual

Replacement Fuses

RISK OF EXPOSURE TO EXCESSIVE ULTROVIOLET (UV) RADIATION:
Change shields and lenses if they have become visibly damaged to such
an extent that their effectiveness is impaired, for example by cracks or
deep scratches.
Never look directly at the lamp while lamp is on.
Do not operate without complete lamp enclosure in place or when lens
is damaged. Serious injury may result from the generation of ozone by
this lamp system. A proper means of venting must be provided.

RISK OF POSSIBLE LAMP EXPLOSION:
Do not open for five minutes after switching off.
Service and maintenance should be performed only by qualified
personnel as determined by the high-pressure lighting fixture
manufacturer.

Wear eye and hand protection when re-lamping.

DANGER-INTENSE HEAT:
Equipment surfaces may reach temperatures up to 150° C (302° F).
Allow the fixture to cool before handling.
This equipment is designed for use with a Philips® MSR Gold SA/SE
metal halide lamp only. Use of any other type lamp may be hazardous
and may void the warranty.

Replacing the Lamp

3-phase

driver boards

One fuse plus one extra on the each board Pan or Tilt board-related motors and

fans will be off.

LED Control
Board

One Fuse

LEDs won’t light

Fuse

Fuse Type and Rating

Manufacturer HES Part Number

Motor Power Supply Input

2.5 A, 250 V, Slow Blow

Littelfuse

90403027EF

Motor Power Supply Output

5 A 250 V, Slow Blow

Littelfuse

90403012EF

2-phase Driver Boards

2.5 A, 125 V, Slow Blow SMF

Littelfuse

90402016EF

3-phase Pan and Tilt Board
LED Control Board

5A, 125V, Slow Blow SMF

Littelfuse

90412027EF

Lamp Power Supply Input

20A, 250V, Very Fast

Bussmann

90403030EF

Fuse

Fuse Location and Access

Symptom of Failure